News

Correct Operation Procedure Of Solvent Recovery Machine

Feb 02, 2020 Leave a message

1. Preparation

Prepare an empty bucket with a volume equal to the amount of solvent to be added to hold the recovered clean solvent.

Clean solvent collection barrels must be made of materials that will not be corroded by the recovered solvent or other impurities in the solvent and should not be conductive.


2, Check the solvent collection pipe, exhaust pipe and the barrel lid gasket of the solvent recovery machine

Before recovering the solvent, check the clean solvent collection tube for blockage or air leakage, and make sure that the sealing gasket of the steam drum lid is intact and free of air leakage.


3. Check if there is air leakage in the recycling machine

Release the knob of the recycling bucket lid and remove the bucket lid

Cut the power supply

Use 0.2bar compressed air to blow into the recovery machine from the solvent collection tube

After confirming that the compressed air can be smoothly blown out from the steam inlet pipe in the distillation barrel, close the lid

Install the bucket lid bolt and tighten the knob of the bucket lid, and continue to let the compressed air into the machine until the air pressure reaches 0.2bar

wait a minute

Check if the barometer shows 0.2bar

If the air pressure is less than 0.2bar, please do not recycle the solvent and notify the equipment management personnel.


4. Preparation before feeding

Solvents are generally dangerous. Therefore, be careful when handling and dumping waste solvents into the distillation barrel. Do not allow solvents to splash on the skin or inhale volatile gases from the solvents. The process should pay attention to:

Confirm that the last recovery distillation has ended normally

The temperature of the recycling machine has cooled down

The sealing surface is clean and the distillation barrel is empty and clean


5.Feeding

Release the knob of the lid of the distillation tank and remove the lid

Pour the prepared waste solvent into the distillation barrel, and be careful not to exceed the maximum level line marked in the barrel when feeding.

Close the lid

Close the hinged lid and close the lid tightly


6. Turn on the switch for recycling

Before starting the recovery work, make sure that the lid of the distillation tank is closed.

Turn the switch to the on position, the fan will start; press the RUN program key to make the RUN lamp on the meter flash.

Observe that the work indicator is lit and the RUN program indicator is blinking to indicate that the solvent recovery machine has been working normally

The steam cooling fan should start to rotate at this time

Do not touch the upper part of the distillation barrel when the solvent recovery machine is in operation to avoid burns.